Overview of Dew Point Analyzer In winter, we all see such a phenomenon. Due to the low outdoor temperature, the humid and hot indoor air will condense on the window glass, making the window glass blurred. If we observe and study carefully, if we turn on the dehumidifier indoors to gradually remove the humidity in […]
Blog
Introduce the advantages and disadvantages of several dew point analyzers
In principle, the main mainstream dew point analyzers can be divided into chilled mirror type, alumina capacitor type, film capacitor type, polymer capacitor type and so on. Among them, alumina capacitive dew point and dew point analyzers are generally used for measurement in the low humidity range, while chilled mirror and film capacitive dew point […]
Preparation of Zirconia Oxygen Sensor
The ceramic elements mainly used in the chip wide-area oxygen sensor include a porous protective layer, a solid electrolyte, a diffusion barrier, and a support layer. The solid electrolyte is a high-temperature conductive ceramic, and compactness is an important factor in reducing the impedance of the solid electrolyte, increasing the conductivity, and improving the mechanical […]
Types of Zirconia Oxygen Sensor
1.1. Concentration type (Nernst type) zirconia oxygen sensor The practical application of ZrO2 oxygen sensor has successfully realized the control of the air-fuel ratio of automobile engines. The central part is the Y2O3 stable ZrO2 (YSZ) solid electrolyte. Y3+ and Zr4+ are not equivalently replaced, and a large number of oxygen ion vacancies are generated […]
Structure type of zirconia oxygen probe
1. Sampling detection type oxygen probe The sampling detection method is to introduce the measured gas into the zirconia detection chamber through the guiding tube, and then heat the zirconia to the working temperature (above 750°C) through the heating element. Zirconia is generally tubular, and the electrode is porous platinum electrode (Figure 2). The advantage […]
The principle and advantages of zirconia sensor
The zirconia sensor used for combustion atmosphere measurement and control can not only stabilize and improve product quality, but also has the advantage of shortening the production cycle and saving energy. The zirconia sensor is designed in an environment of 650°C or higher using the oxygen ion conductivity of stable zirconia ceramics. Under certain temperature […]
The principle of zirconia oxygen sensor
The working principle of zirconia oxygen sensor: The zirconia oxygen sensor is designed using the oxygen ion conductivity of stable zirconia ceramics in an environment above 650°C. Under certain temperature conditions, if there are different partial pressures of oxygen (ie oxygen concentration) in the gas on both sides of the zirconia bulk ceramic, a series […]
Zirconia sensor structure
The structure of the zirconia sensor is that a zirconia film is sandwiched between two Pt electrodes. The oxygen ions in the zirconia can move freely at high temperatures (above 700°C), and can conduct oxygen ions but not. When the oxygen concentration on both sides of the zirconia film is different, a voltage is generated […]
Zirconia Oxygen Analyzer
working principle: The zirconium oxide oxygen analyzer converts the electromotive force of the oxygen concentration difference into a standard voltage signal linearly related to the oxygen content of the measured gas by the detection instrument, and inputs it to the input terminal of the digital instrument, and inputs it to the CPU of the instrument […]
The working principle of quartz crystal sensor
The principle is the piezoelectric effect of quartz crystal. When the quartz crystal is under pressure, the positive and negative charges will be gathered like two opposite surfaces. The quartz crystal is a capacitor, which gathers positive charges on one side and negative charges on the other. This amount of charge It is proportional to […]